3,157 research outputs found
Development of an embedded Fabry Perot Fiber Optic Strain Rosette Sensor (FP-FOSRS)
We investigate the feasibility of utilizing a Fabry-Perot Fiber Optic Strain Rosette Sensor (FP-FOSRS) for the evaluation of the internal strain state of a material system. We briefly describe the manufacturing process for this sensor and point out some potential problem areas. Results of an embedded FP-FOSRS in an epoxy matrix with external resistance strain gauges applied for comparative purposes are presented. We show that the internal and external strain measurements are in close agreement. This work lays the foundation for embedding this sensor in actual composite laminas
Constraining Radon Backgrounds in LZ
The LZ dark matter detector, like many other rare-event searches, will suffer
from backgrounds due to the radioactive decay of radon daughters. In order to
achieve its science goals, the concentration of radon within the xenon should
not exceed Bq/kg, or 20 mBq total within its 10 tonnes. The LZ
collaboration is in the midst of a program to screen all significant components
in contact with the xenon. The four institutions involved in this effort have
begun sharing two cross-calibration sources to ensure consistent measurement
results across multiple distinct devices. We present here five preliminary
screening results, some mitigation strategies that will reduce the amount of
radon produced by the most problematic components, and a summary of the current
estimate of radon emanation throughout the detector. This best estimate totals
mBq, sufficiently low to meet the detector's science goals.Comment: Low Radioactivity Techniques (LRT) 2017 Workshop Proceedings. 6
pages; 3 figure
Nuclear Physics Neutrino PreTown Meeting: Summary and Recommendations
In preparation for the nuclear physics Long Range Plan exercise, a group of
104 neutrino physicists met in Seattle September 21-23 to discuss both the
present state of the field and the new opportunities of the next decade. This
report summarizes the conclusions of that meeting and presents its
recommendations. Further information is available at the workshop's web site.
This report will be further reviewed at the upcoming Oakland Town Meeting.Comment: Latex, 31 pages. This version has been updated to include final
Comments from the working group
Enhanced Fusion-Evaporation Cross Sections in Neutron-Rich Sn on Ni
Evaporation residue cross sections have been measured with neutron-rich
radioactive Sn beams on Ni in the vicinity of the Coulomb
barrier. The average beam intensity was particles per second
and the smallest cross section measured was less than 5 mb. Large subbarrier
fusion enhancement was observed. Coupled-channels calculations taking into
account inelastic excitation and neutron transfer underpredict the measured
cross sections below the barrier.Comment: 4 pages including 1 table and 3 figure
An Illustration of Inverse Probability Weighting to Estimate Policy-Relevant Causal Effects
Traditional epidemiologic approaches allow us to compare counterfactual outcomes under 2 exposure distributions, usually 100% exposed and 100% unexposed. However, to estimate the population health effect of a proposed intervention, one may wish to compare factual outcomes under the observed exposure distribution to counterfactual outcomes under the exposure distribution produced by an intervention. Here, we used inverse probability weights to compare the 5-year mortality risk under observed antiretroviral therapy treatment plans to the 5-year mortality risk that would had been observed under an intervention in which all patients initiated therapy immediately upon entry into care among patients positive for human immunodeficiency virus in the US Centers for AIDS Research Network of Integrated Clinical Systems multisite cohort study between 1998 and 2013. Therapy-naïve patients (n = 14,700) were followed from entry into care until death, loss to follow-up, or censoring at 5 years or on December 31, 2013. The 5-year cumulative incidence of mortality was 11.65% under observed treatment plans and 10.10% under the intervention, yielding a risk difference of −1.57% (95% confidence interval: −3.08, −0.06). Comparing outcomes under the intervention with outcomes under observed treatment plans provides meaningful information about the potential consequences of new US guidelines to treat all patients with human immunodeficiency virus regardless of CD4 cell count under actual clinical conditions
- …